Restaurant drain maintenance comes down to three things: keeping fats, oils and grease (FOG) out of the pipes, having your grease interceptor cleaned on the schedule Metro Vancouver sets, and getting the lines professionally cleaned and inspected before a backup closes your kitchen. This guide covers all three for operators in Vancouver, Richmond, Burnaby, New Westminster and the North Shore, including what the regional rules say, what your staff should do every shift and what a professional visit should include.
TL;DR
- In Metro Vancouver, commercial kitchens must have grease interceptors pumped out every 90 days or when FOG and solids reach 25% of the wastewater depth, whichever comes first, and keep records of every cleanout.
- Most clogs start at the prep sink and dish pit. Scraping plates and pans into the bin before washing, fitting strainers and training staff prevent the majority of them.
- Do not add enzymes, solvents, bacteria or hot water to an interceptor. Metro Vancouver’s bylaw prohibits it.
- Slow drains, odours and gurgling are early warnings. Call a plumber when you see them, not after sewage reaches the floor.
- A scheduled hydro-jetting and camera visit costs far less than an emergency shutdown during service.
Table of Contents
- Why restaurant drains fail faster than any other drains
- What the Metro Vancouver rules require
- The daily routine that prevents most clogs
- Your weekly and monthly checklist
- What a proper interceptor cleaning looks like
- What restaurants use to clear commercial kitchen drains
- Warning signs: when to call a plumber
- How we approach restaurant drain maintenance
- Book drain cleaning for your kitchen
- Planning around the building, not just the kitchen
- FAQ
- Sources
Why restaurant drains fail faster than any other drains
A home kitchen sends a few pots and plates down the drain each day. A restaurant sends hundreds of covers’ worth of cooking residue, dish water and floor wash through the same pipe diameter. Fat is the main culprit. It leaves the dish machine as a hot liquid, cools in the pipe and sticks to the wall. Food solids catch on it, and the pipe narrows a little more each week until one busy Saturday it closes.
The problem is regional, not just a matter for individual kitchens. Metro Vancouver reports that FOG buildup in pipes and equipment reduces flow capacity and increases maintenance costs, at more than $3 million a year across the region. The same report says inspections are prioritized around geographic hot spots where municipal staff find FOG accumulating in sewers and pump stations. If your kitchen sits in one of those areas, you are more likely to get a visit.
The report also points to a human factor: frequent ownership turnover and limited awareness of bylaws in the restaurant sector are named as major barriers to compliance. If you recently took over a lease, ask the previous operator or the landlord for the interceptor’s service records and find out what type of interceptor you have and where it sits. Many new owners discover the interceptor only when it overflows.
What the Metro Vancouver rules require
Two documents matter for a kitchen in Greater Vancouver: the region’s grease interceptor requirements page and the Food Sector bylaw, No. 365. In plain terms:
- Pump-out frequency. Commercial and institutional kitchens must have the interceptor pumped out every 90 days or sooner if FOG and solids reach 25% of the wastewater depth. The 25% trigger is the one busy kitchens miss. A high-volume fryer line can hit it well before 90 days.
- Records. Food sector establishments must keep records of grease interceptor cleanouts and maintenance. Keep the service invoices where an inspector can find them, not in a former manager’s email.
- No additives. The bylaw prohibits adding enzymes, solvents, hot water, bacteria or other biological or chemical substances to an interceptor to help FOG pass through. That surprises operators who have been sold a bacterial dosing product or who flush the interceptor with a kettle of boiling water. The idea is to capture the grease and remove it physically, not to push it downstream where it solidifies in the municipal sewer.
Requirements differ across Canada. Calgary, for example, requires interceptors to be serviced at least once every four weeks under its own wastewater bylaw, and Toronto requires establishments to keep servicing records and training records on site for at least seven years. Those figures are not your rules if you operate in Metro Vancouver, but they show where the bar is set elsewhere and they are a useful benchmark if your kitchen is very high-volume. For the specifics of your municipality, check the regional page above and ask your city’s sewer department.
The daily routine that prevents most clogs
The cheapest drain maintenance happens before anything reaches the pipe. Municipal guidance from Toronto’s code of practice for food service lists the same habits any good kitchen manager already knows. Adapted for a Vancouver line:
- Scrape before you wash. Pans, plates and fryer baskets are scraped into the bin, not rinsed into the sink. Waste oil goes into a container for collection, never into a floor drain.
- Strainers on every sink and floor drain. A basket strainer costs a few dollars and stops rice, lemon rinds, labels and shredded lettuce. Empty it into the bin at every close.
- Absorb spills, don’t wash them down. Use absorbent material for oil spills and sweep it up. A floor drain is not a spill kit.
- Post signs. Put “no fats, oils or grease down the drain” signs at the dish pit, the prep sinks and the mop sink. New hires read signs faster than they read manuals.
- Train, and repeat. Make waste handling and spill response part of onboarding and review it regularly. Restaurants with high turnover need this more, not less.
- Skip the garbage grinder. Toronto’s guidance recommends avoiding food garbage grinders, since they push more solids and grease into the wastewater. If you have one, ask yourself whether the bin is a better option.
A word on hot water. Flushing drains with hot water is a common tip in kitchen blogs, and for a sink or floor drain a weekly hot flush is harmless. Do not do it into the grease interceptor, though, because the bylaw named above bans hot water as an additive to help FOG pass through. If you are unsure which drains feed the interceptor, ask a plumber to trace them.
Your weekly and monthly checklist
Small inspections catch problems while they are still cheap. A simple rotation works for most kitchens:
| Frequency | Task | Who |
|---|---|---|
| Every close | Empty and rinse strainers, wipe drain covers, check that floor drains are clear | Closing crew |
| Weekly | Check for slow sinks, odours or standing water around floor drains; flush floor drains with water | Kitchen manager |
| Monthly | Open the interceptor lid and look at the FOG layer; check the record log is up to date | Manager or chef |
| Every 90 days at most | Professional interceptor pump-out and inspection | Licensed service provider |
| Once or twice a year | Hydro-jetting of kitchen lines and a camera inspection of the branch and main | Plumber |
The monthly look matters. Calgary’s guidance says to clean the interceptor when the FOG layer is at least 2 inches thick. That is a Calgary rule of thumb, but it makes a handy visual cue: if you can measure a thick cap of grease well before the 90-day mark, book the next pump-out early instead of waiting for the calendar.
For surfaces around the line, such as hood filters, walls and tile, grease needs a different kind of attention. Read about removing kitchen grease professionally to see why a degreasing job is not the same as clearing a pipe, and plan the two as separate tasks.
What a proper interceptor cleaning looks like
Not all pump-outs are equal. Metro Vancouver publishes a cleaning guide for service providers that describes what the job involves: pumping out the contents, clearing the inlet and outlet, removing and cleaning the baffles and screens, and inspecting the parts for damage. The provider should also record the interceptor’s condition and note any damaged components that need repair or replacement.
Use that as a checklist when you get your invoice:
- Was the whole contents removed, not just the top layer of grease?
- Were the baffles and screens taken out and cleaned?
- Did the invoice record the condition of the unit and flag worn parts?
- Did you get a document you can show an inspector?
If the answer to any of these is no, you paid for a partial service. Calgary’s equivalent instructions add scraping the walls and baffles and rinsing the interceptor, which is a sound standard for any kitchen.
Staff have a role too. Municipal guidance asks staff to dispose of FOG, food waste and interceptor contents properly and to avoid adding any agents to the interceptor. The waste hauler takes the contents away; nobody should be pouring them into a sink or storm drain.

What restaurants use to clear commercial kitchen drains
When a drain does slow down, there are four basic options. Which one fits depends on what is in the pipe.

Drain snake (auger). A rotating cable that punches a hole through a blockage. It works for a soft plug near the fixture, but in a grease-lined pipe it often bores a channel and leaves the walls coated. The clog returns in weeks.
Hydro-jetting. Water at high pressure is fed through a hose and nozzle, scouring the grease and scale from the pipe wall and flushing it downstream. It is the standard answer for grease-loaded kitchen lines because it cleans the whole pipe, not just the centre. We cover the trade-offs in our comparison of hydro-jetting and snaking.
Camera inspection. A small camera on a flexible cable shows what is wrong: grease, a sagging section, a broken joint or tree roots. Doing this before jetting means you fix the real cause. See our notes on sewer camera inspection for what the report should contain.
Chemical drain cleaners. We advise against them in a commercial kitchen. They rarely clear a heavy grease load, they can damage older pipe and fittings and they are unsafe for staff handling them. As the bylaw also bans chemical additives in interceptors, anything that ends up in the interceptor line is a risk.
If a drain has backed up more than once in the same spot, the cause is probably not what is in the pipe but the pipe itself: a low spot, a damaged section or roots. Our guide on repeat sewer clogs from tree roots explains the camera-first approach, which applies to a restaurant’s outdoor lateral as much as a house’s.
Warning signs: when to call a plumber
Calgary’s guidance and general plumbing practice agree on the signs. Call before a backup if you see:
- Water draining slowly from the dish sink, prep sink or floor drains
- Persistent odours from drains or around the interceptor
- Gurgling when another fixture is used
- Standing water in floor drains after the kitchen is washed down
- Grease reaching a thick layer in the interceptor well before the next scheduled pump-out
- Sewage or grey water coming up in a drain, which needs an emergency call straight away
If sewage is coming up into a food prep area, stop food preparation in that zone and call a plumber immediately. Whether you can reopen is a question for your health inspector, so call Vancouver Coastal Health or your local health authority about any closure rules that apply to your situation.
After-hours is when kitchens are busiest and plumbers are hardest to reach. That is a good reason to have a provider on file before you need one, and to choose one with 24/7 availability.
How we approach restaurant drain maintenance
We’ve worked on Greater Vancouver plumbing for more than 20 years, and the pattern in kitchens is consistent. The restaurants that call us at 9 p.m. on a Friday are almost never the ones with a maintenance schedule. They are the ones who treated drains as something to deal with when they stopped working.
Here is our view, and what we would tell an owner across the counter:
- Schedule it like you schedule the hood cleaning. Put interceptor dates and jetting visits in the same calendar as your fire-safety and pest control. A calendar entry is cheaper than a closed dining room.
- Look before you jet. A camera run tells us whether a drain needs cleaning or repair. Sometimes it saves you from paying to clean a pipe that is already failing.
- Keep the paperwork. Your records are your proof of compliance. We note what we find in each visit so you have it in writing.
- Train staff first. No contractor can out-clean a kitchen that sends fryer oil down the dish pit every night.
- Ask for pricing up front. We work on transparent pricing with no hidden fees, and we’d rather explain the scope before we start than surprise you after.
Our team is certified, available around the clock and backed by a satisfaction guarantee. That matters for restaurants, where you can’t wait until Monday.
— Austin
Book drain cleaning for your kitchen
We provide hydro-jetting, sewer camera inspections, drain cleaning and emergency plumbing for commercial clients in Vancouver, Richmond, New Westminster, Burnaby and the North Shore. Our drain cleaning service in Vancouver covers kitchen lines and floor drains, and our New Westminster drain cleaning team covers the eastern side of the region. To set up a first visit or to ask what a maintenance plan would look like for your kitchen, contact us through High Pressure Mechanical. Our prices are given after we know the scope of the job, so you know what you are paying for before we start.
If you manage a building with several tenants, including food outlets on the ground floor, our strata mechanical maintenance program helps coordinate shared plumbing and heating checks.
Planning around the building, not just the kitchen
Many restaurants lease their space, and that changes who is responsible for what. Interceptors and the main sewer line can fall under different parties: the tenant often manages the interceptor and kitchen branches, while the landlord or strata owns the main stack and outdoor lateral. Check your lease before an emergency and write down who calls whom.
Property managers and landlords should treat the kitchen tenant’s drains as shared risk. A restaurant backup can reach the units below or the common lines. Our article on common rental property plumbing failures outlines the pattern, and our guide to creating a plumbing maintenance schedule is a good template to adapt for commercial use.
Knowing where your cleanout is also saves time in an emergency. A plumber can start work faster if the access point is marked and clear. Our guide to finding your sewer cleanout walks through how to locate it with the city’s mapping tools.
FAQ
How often should a restaurant’s drains be cleaned?
In Metro Vancouver, the grease interceptor must be pumped out at least every 90 days, or sooner if FOG and solids reach 25% of the wastewater depth. Kitchen branch lines and floor drains aren’t set by the same rule, but many operators schedule hydro-jetting once or twice a year, more often for fryer-heavy menus. Your plumber can advise on a frequency after seeing a camera inspection.
Can I use enzymes or bacteria products in my grease interceptor?
No. Metro Vancouver’s Food Sector bylaw prohibits adding enzymes, solvents, hot water, bacteria or other biological or chemical substances to an interceptor to help FOG pass through. The correct fix is physical removal by pumping out and cleaning the unit.
What do restaurants use to clear a clogged kitchen drain?
For light blockages, a drain snake can work. For grease-lined pipes, professionals use hydro-jetting, which scours the pipe wall with high-pressure water, often after a camera inspection to see the cause. Chemical drain cleaners are a poor choice because they rarely cut through heavy grease and can harm pipes.
Do I need to keep records of drain and interceptor service?
Yes, food sector establishments in Metro Vancouver must keep records of grease interceptor cleanouts and maintenance. Keep the invoices from your service provider showing the date, what was done and the condition of the unit, and store them where a manager or inspector can find them quickly.
What should I do if a floor drain starts backing up during service?
Stop sending water and waste to that drain, keep food and utensils away from the affected area and call a 24/7 plumber. If sewage reaches a food prep area, contact your local health authority about whether you can keep operating.
Sources
- Grease Interceptor Requirements, Metro Vancouver
- Greater Vancouver Sewerage and Drainage District Food Sector Bylaw No. 365
- Grease Interceptor Cleaning Guide for Service Providers, Metro Vancouver
- GVS&DD committee information items, May 2025
- Kitchen and Outdoor Practices for Food Service Establishments, City of Toronto
- Food service establishments, City of Calgary
- Wastewater Compliance and Best Management Practices, City of Calgary
No comments yet.