A sump pump that runs constantly is either working against a lot of incoming water, stuck because of a failed float switch, or pushing water that flows straight back into the pit. Pentair says continuous running can mean heavy inflow or a float switch stuck in the ON position. Below you will find how to tell which one you have, what is safe to check yourself, and the point where it is time to hand it to a licensed plumber.

High Pressure Mechanical
Stop Sump Pump Trouble Early
High Pressure Mechanical provides plumbing repairs in Vancouver, including help with household issues such as pumps that run constantly.

Visit High Pressure Mechanical

TL;DR

  • Running nonstop during a downpour can be normal. Running nonstop in dry weather, or with an empty pit, is not.
  • The usual suspects are a stuck float switch, a failed or missing check valve, a discharge line that drains back toward the house, and a pit that is too small for the pump.
  • Unplug the pump and shut off power before you put a hand near the pit. Never stand in water while you work.
  • If water is rising in the pit and the pump cannot keep up, bail the pit by hand, switch to a backup pump and call a plumber.
  • Test the pump on a schedule and plan to replace it around the 10-year mark.

Table of Contents

First question: is it actually a problem?

Sump pumps exist to run. As water rises in the pit, a float lifts and triggers the switch, and the pump pushes water out through a discharge pipe fitted with a check valve to help prevent backflow, as Canada.ca describes. In Greater Vancouver, where the wet season brings days of steady rain and a saturated water table, a pump that cycles often is simply doing its job.

So sort your situation into one of three groups.

What you see Likely meaning What to do
Pump runs during or just after heavy rain, then stops once the pit drains Normal response to high inflow Watch it. Confirm it shuts off within a reasonable time after the rain eases
Pump runs every minute or two in a storm Heavy inflow, possibly a check valve or pit sizing issue Check the discharge and check valve, keep an eye on the water level
Pump runs in dry weather, or runs with little or no water in the pit Mechanical fault: stuck float, failed switch, air lock, or recirculating water Unplug it and troubleshoot, or call a plumber

A Bob Vila explainer puts it plainly: in most cases it is not normal for a pump to run nonstop. If yours has been going for hours with no rain to blame, treat it as a fault.

What about every 30 seconds or every minute?

During a heavy storm, a pump cycling every minute or two is common. One 2026 guide notes that a pump running every 30 seconds is not normal for long and can point to very heavy inflow or short-cycling. We would not hang a diagnosis on a number alone. What matters is the trend: if the cycling continues long after the rain has eased, something other than groundwater is filling the pit.

Why your sump pump keeps running

A stuck or failed float switch

This is the most common mechanical cause. The float rides up as the pit fills and drops as it empties. If it jams against the pit wall, tangles with the power cord, snags on the discharge pipe or the switch itself fails in the closed position, the pump gets the signal to run even when the pit is dry.

Signs: the pit is empty or nearly empty, the pump is humming, and you hear the motor spinning with little water moving. Running a pump dry is hard on it, so deal with this one quickly.

A failed or missing check valve

The check valve sits on the discharge line and stops pumped water from falling back into the pit when the pump shuts off. Federal Pump recommends a check valve and a shut-off valve for each pump, for backflow prevention and for stopping flow during testing and servicing.

When the valve sticks open or fails, the water in the vertical pipe drops back into the pit every time the pump stops. The pit refills immediately, the float rises, and the pump starts again. That is short-cycling, and it can look like the pump never stops. A telltale sound is a rush or gurgle of water coming back down the pipe right after the motor cuts out.

A failed or missing check valve

Water that returns to the pit

If the discharge pipe ends too close to the foundation, water can soak back into the ground, travel to the drain tile and flow right back into the pit. One guide describes this as the pump continuously lifting the same water. On a wet day it can feel like an endless loop.

The fix is to carry the discharge well away from the house and to ground that slopes away from it. Where freezing is possible, the ICLR notes that the discharge line should be raised above ground to prevent freezing and ice blockage. That matters in the colder snaps we see in the Lower Mainland, and in the Fraser Valley and the North Shore where it can get colder still.

A blocked or frozen discharge line

If water cannot leave, the pump keeps trying. Debris in the line, a kinked flexible hose, a clogged outlet screen or an ice plug all produce a pump that runs, sounds strained and moves very little water. Walk the line outside and look for crushed sections, buried ends and anything covering the outlet.

Ice and debris obstructing a sump discharge outlet

A pit that is too small, or a pump that is wrong for the pit

A small basin fills quickly, so the pump starts and stops constantly. If the float has no room to travel, it can also trigger early or stick. It is tempting to answer this with a bigger pump, but Regional Stormwater Management points out that a larger pump is not automatically better when the discharge, power, check valve or pit is what causes the short-cycling or limits the flow. Matching the pit, pump and discharge is a job for someone who sizes these systems regularly.

Genuinely high groundwater

Sometimes nothing is wrong. After a long atmospheric river, soil near your home can stay saturated for days and the pump runs until the water table drops. Then the right questions are about capacity and backup, not repair: is the pump keeping the pit level down, is the alarm working, and would the house stay dry if the power went out?

How to troubleshoot safely, step by step

Safety comes before diagnosis. Technical manuals from Federal Pump and M3 Floodtec agree that power must be disconnected before any inspection or repair, to avoid electrical shock. M3 Floodtec adds: shut off the main breaker and unplug the pump, wear insulated protective-soled shoes, and never stand in water.

If the floor around the pit is wet and you cannot reach the panel or outlet without stepping through water, stop and call a licensed electrician or plumber. A basement that is already flooding is not a place for a do-it-yourself check.

  1. Look and listen first. Is it raining? Is the pit full, half full or empty? Does the motor hum, grind or spin quietly? Note whether water is coming down the discharge pipe after each cycle.
  2. Cut the power. Shut off the breaker and unplug the pump, in dry conditions only.
  3. Check the float. Lift the float by hand and see whether it moves freely and returns. Clear anything touching it. A float that will not move freely, or a switch that stays on when the float is down, needs replacing.
  4. Inspect the check valve. Look for the arrow pointing away from the pump, a valve that is installed backward, or one that clicks and holds poorly. If water falls back every cycle, the valve is suspect.
  5. Walk the discharge line. Look for blockages, kinks, ice and an outlet that sits too close to the foundation.
  6. Test with water. The ICLR advises testing sump pumps regularly, as often as monthly or bi-monthly in high water table areas, by pouring water into the pit to confirm the pump starts and discharges freely away from the foundation. Use the same test after any fix. If the pump starts, empties the pit and stops, you have fixed it. If not, stop.
  7. Restore power and watch a full cycle. Stay until the pump has run and shut off at least once.

Some pumps can be reset by unplugging for a few minutes, which can clear a thermal overload or a one-off glitch. Treat that as a diagnostic, not a repair. If the problem returns, there is a cause behind it.

What if it won’t stop and the water is rising?

This is the situation that costs money. Act in this order:

  1. Keep clear of standing water near electrical outlets and the panel.
  2. If the pit is rising toward the top and it is safe to do so, bail it by hand or with a bucket. The ICLR notes that an alarm can warn when sump water reaches a higher-than-usual level, allowing action such as an emergency backup pump or hand-bailing the pit.
  3. Bring in a backup pump if you have one. Canada.ca encourages property owners to have a backup system on an independent power source, such as a battery or generator, since power outages are a common cause of pump failure.
  4. Call a plumber right away. If water has already reached finished space, the cleanup clock starts now.

We get this call most often in the middle of a storm, when the power is flickering and the pump is the last thing between the basement and the street. That is exactly why we answer around the clock.

How long can a pump run before it burns out?

There is no single safe number. It depends on the motor, how much water the pump is moving, how hot the water is and whether the pump is submerged and cooled or running dry. A pump moving real water through a clear discharge line is working as designed; a pump spinning against a blocked line or an empty pit is heating up with nothing to cool it. Check your manufacturer’s manual for the duty rating on your model, and treat any run that continues for hours with no rain as a reason to act, not to wait.

Why a running pump is also a warning about age

Pumps wear out. Canada.ca says sump pumps should generally be replaced every 10 years, though you should check the manufacturer’s recommendation. The ICLR lists the common failure paths as float or switch problems, pump failure and power-supply failure, and warns that damage can be significant if a problem is not caught early.

If your pump is near or past 10 years and has started running constantly, repairing a float on a tired motor is often a short-term patch. Replacing the whole assembly, with a new check valve and a properly routed discharge, tends to be the more reliable path.

A written routine helps. Our guide to creating a plumbing maintenance schedule is a good place to add a monthly pit test during the wet season. For the general principles behind scheduled upkeep, these preventive maintenance steps explain how regular checks reduce unplanned failures.

Our perspective

Most running-pump calls we hear about are not mysteries. They are a float that jammed, a check valve that gave up, or a discharge line that was never routed far enough from the house. The pump gets blamed, but the system around it is usually the problem.

Our advice is to treat a nonstop pump as a symptom worth a proper look, not a nuisance to silence by unplugging it. Unplugging in a rainstorm can trade a noisy pump for a flooded basement. Test it, find the cause, and fix that.

We also agree with the guidance from Canada.ca and the ICLR that a licensed plumber should decide whether a sump system suits the home and install it, because a wrong setup can fail at the worst moment. Our technicians are certified, we quote with transparent pricing and no hidden fees, and we stand behind the work with a satisfaction guarantee. If water is already where it should not be, our team is available 24/7 and also handles water damage and general troubleshooting across Greater Vancouver.

Austin

When to call a plumber

Call right away if any of these apply:

  • The pump runs for hours in dry weather.
  • The pit is full and water is still rising.
  • You smell burning, see smoke, or the breaker trips when the pump starts.
  • You find water on the floor around the pit or near electrical equipment.
  • You have replaced the float or check valve and the problem keeps returning.
  • The pump is about 10 years old and has begun acting up.

Our plain-language guide to when to call a plumber walks through the questions that separate a quick DIY check from a job for a professional. If water has already escaped the pit, the comparison in emergency leak repair services shows what to expect from a call-out. And if you rent out a basement suite, see how plumbing in basement suites affects who is responsible for what.

Book help before the next storm

A pump that will not stop deserves a visit before the next atmospheric river, not after it. High Pressure Mechanical provides 24/7 plumbing for homeowners, tenants, landlords and property managers in Vancouver, Richmond, New Westminster, Burnaby and the North Shore, with certified technicians and transparent pricing. Tell us what you are hearing and seeing, and we will help you work out the next step.

High Pressure Mechanical

See our plumbing services or contact us through our plumber page to arrange an inspection or emergency visit.

FAQ

Is it normal for a sump pump to run every 30 seconds during rain?

During a heavy storm, a pump may well cycle every minute or two. Every 30 seconds for a long stretch is not typical and can point to very heavy inflow or short-cycling from a failed check valve or a pit that is too small. If it continues after the rain eases, have the system inspected.

Why does my sump pump run when the pit is empty?

The most likely cause is a float switch that is stuck or has failed in the on position. A check valve that lets water fall back into the pit, or a discharge that returns water to the drain tile, can also make an almost empty pit refill. Unplug the pump and check the float first.

Can I just unplug the pump to make it stop?

Only as a short-term step in dry conditions, to troubleshoot. If groundwater is high, an unplugged pump means water rises in the pit and can reach your floor. Disconnect power safely, find the cause, and have a backup ready while you do.

How long should a sump pump last?

Canada.ca says sump pumps should generally be replaced every 10 years, and you should confirm the manufacturer’s recommendation for your model. A pump that has started running constantly near that age is usually a candidate for replacement rather than another repair.

Should I fix this myself or call a plumber?

Checking the float, the visible discharge line and the outlet is reasonable if the area is dry and the power is off. Installation, sizing and check valve work are better left to a licensed plumber, because Canada.ca and the ICLR both warn that incorrect setups can cause failure or flooding.

Sources