If your boiler is leaking water, turn the heating off, let the system cool, shut off the boiler’s water supply and keep water away from anything electrical. Then call a licensed technician. In British Columbia, boiler and gas work is regulated, so the repair itself is not a do-it-yourself job. A leak can be a loose fitting or a valve doing its job, or it can be a failed heat exchanger. The location of the water and the pressure gauge tell you which. Our Vancouver team handles boiler repair 24/7 across Greater Vancouver, so you do not have to guess.
TL;DR
- Turn the heating off, let the boiler cool, close its water supply and keep water away from electrical parts.
- If you smell rotten eggs or hear hissing, leave the house and call FortisBC at 1-800-663-9911 or 911 from outside.
- Where the water shows up and what the pressure gauge does over a heating cycle narrow down the cause.
- Common causes: a relief valve discharging, a failed expansion vessel, loose connections, corrosion, worn seals and a cracked heat exchanger.
- In BC, repairs to boilers and gas equipment must be done by qualified, authorized people. Book a licensed technician.
Table of Contents
- First steps when water is leaking
- Where the water shows up tells you a lot
- Common causes of a boiler leak
- Read the pressure gauge
- What not to do
- Why BC requires a qualified technician
- Tenants, landlords and property managers
- Repair or replace?
- Preventing the next leak
- Our perspective
- Get a licensed technician to your boiler
- FAQ
- Sources
First steps when water is leaking
Do these in order and stop when the leak stops.
- Turn the heating off at the thermostat. Circulating hot water keeps pressure high and keeps the leak going.
- Let the boiler cool. Hot water can scald, so do not open or touch internal parts.
- Close the water supply to the boiler. This is usually the valve on the cold feed line near the boiler. Closing it stops the system from refilling.
- Switch off power to the boiler if water is near electrical components and you can reach the switch dry. If water is pooling near the panel or outlets, do not step into it. Shut the breaker only if the panel is dry and away from the water.
- Contain the water. Use a bucket or towels and move belongings away. Take photos for your records, since leaks can lead to water damage claims.
- Note the details. Where does the water appear, is the gauge high or low, and does the leak happen only when the heating is on? A technician will ask.
If you smell gas
Most residential boilers in Metro Vancouver burn natural gas. If you smell the rotten-egg odorant or hear hissing, the water leak is secondary. FortisBC advises that you stop what you are doing, avoid cellphones, smoking and electrical switches, go outside leaving doors and windows open, and call 1-800-663-9911 (24 hours) or 911 from outside. The BC Office of the Fire Commissioner adds that you stay outside until an official says it is safe to re-enter, and that only a licensed gas contractor can turn gas back on once it has been shut off.

Where the water shows up tells you a lot
A damp patch tells you water has been somewhere, not where it is coming from right now. A practical test from a York heating firm’s guide: dry the area, wait about half an hour, and see where new water appears first.
| What you see | Likely cause |
|---|---|
| Water dripping from a discharge pipe outside or from the relief valve outlet | The pressure relief valve is releasing water because pressure got too high |
| Water from the bottom of the boiler | Internal seal, pump, valve, pipe connection, heat exchanger or pressure fault |
| Leak only when heating is on | Pressure rise or a seal that opens as the metal expands |
| Pool under one radiator | Usually a loose valve or worn seal on that radiator, not the boiler |
| Damp some distance from the boiler, along a pipe | Corroded joint or pinhole in old copper pipework |
| Brown, rusty water | Corrosion or sludge in the system |
| New damp patch after a cold snap | Frozen or split pipework in an unheated garage, crawlspace or utility area |
Treat the table as a guide, not a verdict. Water can travel along internal components or pipes before it drips from the bottom of the casing, so the drip point does not always mark the failed part.
Common causes of a boiler leak
High pressure and the relief valve
Sealed boilers have a pressure relief valve. If pressure rises too high, the valve releases water automatically to bring it down. Seeing water at that valve is the system protecting itself. The question is why pressure got that high.
A common reason is the expansion vessel. Water expands when heated, and the vessel absorbs the extra volume in a gas cushion. If the vessel loses its charge or its diaphragm fails, pressure climbs sharply as the system heats, the relief valve opens, and the gauge reads low once everything cools. That pattern, low when cold and very high when firing, is a strong clue.

Loose or broken connections and worn seals
Seals between boiler components loosen or break as water expands and contracts through heating cycles. When a seal breaks, water can escape quickly and pressure drops. Pipe joints can also work loose over the years. A small seal failure may start as an occasional drip, but it should be looked at before water reaches electrical components.
Corrosion
Air in the system corrodes copper pipes, radiators and tanks until they crack, a problem even modern boilers can have. Rusty or discoloured water usually points to long-running corrosion and loss of inhibitor, not a sudden new fault. British Gas lists a leaking pump or internal seal and age-related wear among the usual suspects too.
A faulty heat exchanger
This is the serious one. A cracked heat exchanger is the most expensive leak to fix and is more likely in older units. If an older boiler has a heat exchanger leak, the repair-or-replace question comes up. Our guide on why replacement can beat repair walks through it.
Read the pressure gauge
The gauge is the cheapest diagnostic you own. Note the reading when the boiler is cold, again while it is heating, and again after it cools. A normal sealed system sits roughly between 1 and 2 bar, and many Canadian homeowners see about 1.0 to 1.5 bar when cold. Our guide to low boiler pressure explains the range.
- Gauge keeps dropping and you top it up every few days: the system is losing water somewhere, inside the boiler or in the pipework.
- Gauge spikes while heating, then falls when cool: suspect the expansion vessel or filling loop.
- You keep repressurizing without finding the cause: that can signal an expansion vessel or valve fault, and the fix is diagnosis, not more water.
Repeated topping up also dilutes the inhibitor that protects the system from corrosion, because the protection leaves with the lost water.
What not to do
- Do not plug or cap the relief valve discharge. It is a safety device.
- Do not open the boiler casing to chase the leak.
- Do not keep running the boiler for days while it drips onto electrical parts.
- Do not relight or restart gas equipment after a shutdown. In BC only a licensed gas contractor should turn it back on.
Why BC requires a qualified technician
This is a safety and legal point. Under BC’s Gas Safety Regulation, regulated work on gas systems and equipment must be done by someone who holds a certificate of qualification or is otherwise authorized under the regulation, with a limited exception for homeowners under the conditions it sets. Boilers and pressure vessels have their own rules: under the Power Engineers, Boiler, Pressure Vessel and Refrigeration Safety Regulation, except in an emergency, repairs require notifying a safety officer and getting approval of repair procedures and an installation permit. Permits and approvals are part of the job a qualified contractor takes on.
To check a gas contractor yourself, the Office of the Fire Commissioner points residents to Technical Safety BC’s online search tool. Also keep a CO alarm on every level and in sleeping areas if you have fuel-burning appliances.
The same logic applies to a related problem. If the water is coming from a forced-air system instead, see our page on a furnace leaking water.
Tenants, landlords and property managers
If you rent, tell your landlord or property manager right away and photograph the leak and any damage. Landlords and managers get the fastest result by booking one licensed technician who can diagnose and repair, and by keeping a record of every incident. Recurring leaks across a building are often a maintenance pattern, and our rental property plumbing failures guide covers it. If you cannot tell whether the water is from the boiler or a pipe in the wall, these leak detection methods and the steps to confirm a wall leak help.
Repair or replace?
Most leaks from valves, seals, connections or an expansion vessel are repairable. A cracked heat exchanger, widespread corrosion or repeated failures on an older boiler move the conversation toward replacement. The technician should explain what failed, what the repair involves and what it means for the remaining life of the boiler. Also read the warning signs a boiler needs immediate repair.
Preventing the next leak
- Have the boiler serviced annually so valves, seals, pressure and the expansion vessel are checked before they fail. Our boiler maintenance checklist lists what to look at.
- Check the gauge monthly in heating season and write the reading down.
- Keep pipes in unheated garages and crawlspaces insulated before cold snaps.
- Treat rusty water as a warning and book an inspection.
The same discipline applies to other heated-water equipment. Even a hot tub heater that is leaking calls for shutting off power and water first, then professional help.
Our perspective
Most leaking boilers we are called to are not mysteries. The water has a cause, and the cause usually shows in where it appears and what the gauge does. The expensive mistakes come from running the boiler for weeks on a drip, topping up pressure again and again, or opening something that should stay closed.
Our approach is to treat a leak as both a plumbing and a heating problem. We are available 24/7, our technicians are certified, and our pricing is transparent with no hidden fees. We back the work with a satisfaction guarantee. Boiler repair and maintenance, water heater service and sewer camera inspection all come from one team, so you are not passing the problem between trades.
Our advice: shut it down safely, take a few photos, note the gauge, and call early. A small leak caught early is a short visit.
Austin
Get a licensed technician to your boiler
We provide boiler repair and maintenance, water heater service and water damage response for homes and businesses in Vancouver, Richmond, New Westminster, Burnaby and the North Shore, around the clock. See boiler repair in Vancouver or our full list of services, then call with the notes you made about the leak.

For commercial buildings, our HVAC services cover heating systems and preventative maintenance.
FAQ
Why is my boiler dripping water?
The usual causes are a relief valve discharging because pressure is too high, a worn seal or loose connection, corrosion, or a failing expansion vessel. Where the water appears and how the gauge behaves point to the cause. A technician confirms it.
Is a leaking boiler dangerous?
It can be. Water near electrical parts is a shock risk, and a leak can signal a failing component. If you smell gas, leave the house and call FortisBC on 1-800-663-9911 or 911 from outside. For a water-only leak, turn off the heating and water supply and book a technician.
Can I keep using the boiler if the leak is small?
We advise against it. A small drip can become a larger failure, and repeated topping up dilutes corrosion protection. Shut the boiler down and have it inspected.
How do I tell a boiler leak from a pipe leak?
Dry the area and recheck after about half an hour to see where fresh water appears first. A steadily falling gauge points to loss inside the system, a pool under one radiator usually points to that radiator’s valve or seal, and damp away from the boiler can be a corroded pipe.
Can a leaking boiler be repaired?
Often yes, particularly valves, seals, connections and expansion vessels. A cracked heat exchanger on an older boiler is the case where replacement is most often discussed.
Sources
- Gas leaks and odours | FortisBC
- Gas Safety Regulation | BC Laws
- Power Engineers, Boiler, Pressure Vessel and Refrigeration Safety Regulation | BC Laws
- Is my boiler leaking water? | Vaillant
- Why is my boiler leaking? | British Gas
- Boiler Leaking Water: Causes and Whether It Is Urgent
- Boiler Leak: How to Tell If It’s the Boiler, a Pipe, or a…
- Boiler Leaking Water? Causes, What to Do & Repair Advice
No comments yet.